A Revolutionary Single Use Endoscope Lumen Cleaning Device

Channel Working Length
2.8 - 5.0mm id 2200mm approx
 
Warning! not to used in channels less than 2.8mm id
not to used in channels greater than 5.0mm id
   

Introducing a new patented endoscope channel pre cleaning device, the PULL THRU, which can be effectively used to pre clean lumen channels from size 2.8mm to 5 mm with a single pass.

The PULL THRU was designed to significantly reduce the time required to manually pre clean the lumen and to improve the overall efficiency of the pre cleaning process.

The PULL THRU is disposable which removes the need for complicated cleaning & sterilization procedures of traditional brushes. Traditional brushing methods require endoscope channel to be traumatically and repeatedly brushed. Over a period this mechanical brushing technique creates microscopic crevices on the internal channel walls. Contaminated particles are left behind which are embedded in the newly formed crevices making the cleaning process less effective. Also with a passage of time, this continuous and constant abuse damages the endoscope, which then requires expensive maintenance cost and downtime.

The PULL THRU's unique patented five wiper elements design provides a complete circumferential seal in the lumen tube, there by removing the almost all residue from the internal channels in one simple operation. The effect of this multiple wiper seal is to completely wipe the lumen clean, thus providing a simple, smooth, non abrasive, non damaging and time saving method to pre clean endoscope in the most effective way.

Scientifically proven, PULL THRU's single pass operation significantly improves the efficiency of the pre cleaning process as when compared to the cleaning process by traditional brushes even after three brushing cycles.

Pull Thru Multiple Wiper Seal
The unique patented five wiper elements

refillable cassette dispenser
Easy to use refillable cassette dispenser

Pull Thru Refills
Bulk refills available in packs of 3

Single Patient Use Pack (60)

  • How to Use the PULL THRUs
  • How to Refill the Cassette
  • How to Mount the Cassette

(+ click photos for a larger view)

Push Thru cleaning of Pentax Slim Scopes

Video - User Guides for most
popular scopes

Pull Thru Refills
Insert the short tip end in first...
Pull Thru Refills
Pull cleaner through, wipers should pass easily into the channel...
Pull Thru Refills
Pull through the endescope until it has passed completely through the device.

(+ click photos for a larger view)

Open lid by depressing  the side tab and un-clipping  the front latch
Open lid by depressing
the side tab and un-clipping
the front latch
Place and insert end of the  packing sleeve into the up standing pillars...
Place and insert end of the
packing sleeve into the
up standing pillars with the
plastic sleeves on...
Close up of the sleeve end anchoring
Close up of the sleeve end anchoring
Close and latch the lid. Pull Thru are ready to be dispensed
Close and latch the lid.
Pull Thru are ready to be dispensed

Instructions on mount the cassette to come..